HyperLOG X Series Directional Antennas
All HyperLOG® X antennas are ACTIVE antennas, i.e. they are equipped with an extremely low-noise amplifier. This can be operated either via the integrated rechargeable battery (runtime approx. 3-4 hours) or via an enclosed power supply unit. The gain of the antenna could thus be increased to over 45 dBi (previously 5 dBi). The new HyperLOG® X antennas are therefore probably the most sensitive LogPer DF antennas available on the market.
With the HyperLOG® X series, Aaronia offers low-cost active directional antennas that nevertheless meet the highest requirements. The HyperLOG® X series supports a wide frequency range from 380 MHz to 20 GHz. This means that the antennas can be used for measuring (active) radar, cellular radio, WLAN, Blutooth, etc. Each HyperLOG® antenna undergoes rigorous testing in our laboratories before shipping and is equipped with a high-quality gold coating, a high-tech antenna housing (radome) to protect against mechanical damage and environmental influences, an integrated tripod connector and an SMA connector with over-rotation protection.
- High gain for detection of the weakest RF sources
- Specially shaped radome for antenna protection
- Low noise preamplifier with integrated rechargeable battery
- Internal EEprom for reading out calibration data (via USB)
- Coverage of different mobile radio frequencies
- Gold coating for stable performance
- Suitable for field strength and EMC measurements
- Compact and robust design
| Model | HyperLOG 7025 X | HyperLOG 7040 X | HyperLOG 7060 X |
| Design | log-periodic | ||
| Frequency range | 700MHz-2.5GHz | 700MHz-4GHz | 700MHz-6GHz |
| Preamp Noise | Linear increase, 100MHz: 3,5dB, 3GHz: 4dB, 6GHz: 4,5dB | ||
| Preamp Gain (typ.) | Linear fall-off. 1MHz: 40dB; 3GHz: 37,5dB; 6GHz: 35dB | ||
| Nominal impedance | 50 Ohm | ||
| VSWR (typ.) |
| <1:2 |
|
| Gain (typ.) | 44dBi | 44dBi | 45dBi |
| Calibration points | 183 (10MHz-steps) | 333 (10MHz-steps) | 533 (10MHz-steps) |
| HF-Connector | SMA-Connector (18GHz) or N-Connector via Adapter | ||
| Dimensions (L/B/H) | 390x200x25 mm | ||
| Weight | 400g | ||
| Model | HyperLOG 6080 X | HyperLOG 60100 X | HyperLOG 60200 X |
| Design | log-periodic | ||
| Frequency range | 680MHz-8GHz | 680MHz-10GHz | 680MHz-20GHz |
| Preamp Noise | Linear increase, 100MHz: 3,5dB, 3GHz: 4dB, 6GHz: 4,5dB | ||
| Preamp Gain (typ.) | Linear fall-off, 1MHz: 40dB; 3GHz: 37,5dB; 6GHz: 35dB | ||
| Nominal impedance | 50 Ohm | ||
| VSWR (typ.) | <1:2 | ||
| Gain (typ.) | 45dBi | 45dBi | 19dBi |
| Calibration points | 733 (10MHz-Steps) | 933 (10MHz-Steps) | 389 (50MHz-Steps) |
| RF-Connector | SMA-Connector (18GHz) or N-Connector via Adapter | ||
| Dimensions (L/B/H) | 390x200x25 mm | ||
| Weight | 400g | ||
| Model | HyperLOG 4025 X | HyperLOG 4040 X | HyperLOG 4060 X |
| Design | log-periodic | ||
| Frequency range | 400MHz-2.5GHz | 400MHz-4GHz | 400MHz-6GHz |
| Preamp Noise | Linear increase, 100MHz: 3,5dB, 3GHz: 4dB, 6GHz: 4,5dB | ||
| Preamp Gain (typ.) | Linear fall-off, 1MHz: 40dB; 3GHz: 37,5dB; 6GHz: 35dB | ||
| Nominal impedance | 50 Ohm | ||
| VSWR (typ.) | <1:2 | ||
| Gain (typ.) | 44dBi | 44dBi | 45dBi |
| Calibration points | 211 (10MHz-Steps) | 361 (10MHz-Steps) | 561 (50MHz-Steps) |
| RF-Connector | SMA-Connector (18GHz) or N-Connector via Adapter | ||
| Dimensions (L/B/H) | 640x360x30 mm | ||
| Weight | 1400g | ||
| Model | HyperLOG 3080 X | HyperLOG 30100 X | HyperLOG 30200 X |
| Design | log-periodic | ||
| Frequency range | 380MHz-8GHz | 380MHz-10GHz | 380MHz-20GHz |
| Preamp Noise | Linear increase, 100MHz: 3,5dB, 3GHz: 4dB, 6GHz: 4,5dB | ||
| Preamp Gain (typ.) | Linear fall-off, 1MHz: 40dB; 3GHz: 37,5dB; 6GHz: 35dB | ||
| Nominal impedance | 50 Ohm | ||
| VSWR (typ.) | <1:2 | ||
| Gain (typ.) | 45dBi | 45dBi | 19dBi |
| Calibration points | 761 (10MHz-Steps) | 961 (10MHz-Steps) | 394 (50MHz-Steps) |
| RF-Connector | SMA-Connector (18GHz) or N-Connector via Adapter | ||
| Dimensions (L/B/H) | 590x360x30 mm | ||
| Weight | 1400g | ||