PicoVNA® Vector Network Analyzers
The incredible PicoVNA: Low cost, high performance
The PicoVNA 106 and PicoVNA 108 are low cost, small footprint, USB controlled Vector Network Analyzers that offer up to 8.5 GHz of bandwidth with performance that punches well above their weight.
Accurate: With up to 124 dB of dynamic range and RMS trace noise of just 0.005 dB at maximum resolution bandwidth, you know that what you are recording is a true reflection of the device you are measuring.
Fast: Capable of up to 5500 dual-port S-parameter measurements per second; that is, creating a 201-point two-port .s2p file takes less than 38 ms.
Affordable: Not only is the unit itself excellent value, calibration kits are highly affordable and easily repairable, keeping total cost of ownership low.
Reliable: The quad-RX architecture minimizes uncorrectable errors and delays.
Simple: Automated calibration with the E-Cal kit makes it easier and faster to get up and running.
| Mode | PicoVNA 106 | PicoVNA 108 | Conditions |
| Measurement bandwidth | 140 kHz、70 kHz、35 kHz、15 kHz、10 kHz、5 kHz、1 kHz、500 Hz、100 Hz、50 Hz、10 Hz | ||
| Average displayed noise floor | Band(MHz) Typical(dB) Max(dB) | Band(MHz) Typical(dB) Max(dB) 0.3 to 1 -100 -90 1 to 6000 -124 -110 > 6000 -120 -100 | Relative to the test signal level set to maximum power after an S21 calibration. Ports terminated as during the isolation calibration step. |
| Dynamic range (click for graphs) | 0.3 MHz to 10 MHz 10 MHz to 6 GHz | 0.3 MHz to 10 MHz 0.3 MHz to 8.5 GHz | 10 Hz bandwidth Maximum test power: PicoVNA 106: +6 dBm PicoVNA 108: 0 dBm No averaging |
| Temperature stability, typical | 0.02 dB/°C for F < 4 GHz 0.04 dB/°C for F ≥ 4 GHz | Measured after an S21 calibration | |
| Trace noise, dB RMS | Band Typical Max | 201-point sweep covering 1 MHz to 6 GHz or 8.5 GHz. | |
| Spurious responses | -76 dBc( typical),-70 dBc(Max)。 | The main spurious response occurs at close to (2 x RF + 1.3) or (3 x RF + 2.6) MHz, where RF is the test frequency in MHz. For example, when testing a bandpass filter with a centre frequency of, say 1900 MHz, an unwanted response will occur around 632.47 or 949.35 MHz. In all known cases the levels will be as stated. | |